Archieven

Vrije Universiteit Brussel – Analytical, Environmental and Geo- Chemistry

Vrije Universiteit Brussel – Analytical, Environmental and Geo- Chemistry

Vrije Universiteit Brussel
Pleinlaan 2
B-1050 Brussel

Contact
Name
email
phone
website

Research line
Geology, Paleoclimatology, Ecology

Topics
paleoenvironmental research
paleoclimatological research
ecological research

Isotopes
2H, 13C, 15N, 18O, 87Sr

Instruments

Amsterdam VU University – Dept. of Earth Sciences – Stable Isotope Laboratory

Amsterdam VU University – Dept. of Earth Sciences – Stable Isotope Laboratory

De Boelelaan 1085, 1081HV Amsterdam, NL

Contact: 
Hubert Vonhof
h.b.vonhof@vu.nl
31(0)205987366/5987308

Research line:       
Geology

Isotopes:       
13C, 15N, 18O, 2H, 32S

Topics
Paleoclimatology
Paleoceanography
Hydrology
Archeology
Forensics
Reservoir studies (oil gas and water)

Instruments:
DI-IRMS Kiel, GC/IRMS, EA/C/IRMS, EA/P/IRMS

Thermo Finnigan MAT 252 with Kiel device
Thermo Finnigan Delta + with Gasbench II
Thermo Finnigan Delta XP with Flash combustion furnace and TC-EA pyrolysis furnace

Academic Medical Center Amsterdam – Clinical Chemistry / Woman and Child / Endocrinology

Academic Medical Center Amsterdam – Clinical Chemistry /  Woman and Child / Endocrinology

PO Box 22660, 1100DD Amsterdam / Meibergdreef 9, 1100AZ Amsterdam, NL

Contact:
Henk Schierbeek
h.schierbeek@amc.uva.nl
31(0)205666299

Research line
Health and Disease

Topics
metabolic kinetics
amino acids, peptides, carbohydrates, protein synthesis, energy expenditure
neonates, adults, laboratory animals: mouse, rat, pig, baboon
insulin resistance, lungs (surfactant), gut, oxidative stress and malnutrition

Isotopes
13C, 15N, 18O, 2H

Instruments
LC/MS/MS, GC/MS/MS, GC/C/IRMS, EA/C/IRMS, SIRIS, GC/MS, LC/C/IRMS

LCMS\MS, Waters, Premier, Triple quad
LCMS\MS, Waters, Xevo, Triple quad
LCMS\MS, Thermo Fisher, Velos pro, Linear Trap
GCMS\MS, Agilent 7000 GC\QQQ, Triple quad
GCMS, Agilent 5975C, Single quad
GCMS, Agilent 5973, Single quad
GCMS, Agilent 5973, Single quad
IRMS, Thermo Fisher, Delta plus
– GC/C/IRMS (+ Headspace)
IRMS, Thermo Fisher, Delta XP plus
– GC/C/IRMS
– LC/C/IRMS
– TCEA/IRMS
– Con Flow EA/IRMS
Infrared Spectrometer, Fisher, Helifan, CO2 analysis

Amsterdam University – Institute for Biodiversity and Ecosystem Dynamics (IBED)

Amsterdam University – Institute for Biodiversity and Ecosystem Dynamics (IBED)

PO Box 94240, 1090GE Amsterdam
Science Park 904, 1098 XH Amsterdam, NL

Contact
Prof. Karsten kalbitz
K.Kalbitz@uva.nl
31(0)205257434/6637

Cerli Chiara – c.cerli@uva.nl

Research line
Ecology

Topics
With the analyses of C, N, H, and S stable isotopes (δ13C, δ18O, δ15N, δ2H, δ34S) in environmental samples, from soils to sediment and water we study:
–         Effects of changing environmental conditions on the mechanisms and rates of C      stabilization in soils
–         Interactions between land degradation and C sequestration in soils
–         Reconstruction of past environments and climates to improve future predictions
–         Fate of organic pollutants in soils, sediments and water and interactions with organisms exposed to pollution
–         Application of CSIA in forensic science

Isotopes
13C, 15N, 18O, 2H,  32S

Instruments
EA/C/IRMS, EA/P/IRMS, GC/MS, TOC/IRMS

Stable Isotope Ratio Mass Spectrometer IsoPrime 100 (Elementar – Isoprime) connected with:

Elemental Analyzer, vario ISOTOPE cube
·        EA combustion [CO213C, δ18O), N2 (δ15N), H2 (2H), SO234S)]
·        EA pyrolysis (solid) [H2 (2H), CO (δ18O)]
·        EA pyrolysis (liquid) [H2 (2H), CO (δ18O)]

GC/MS, Agilent 7890A GC-MS-FID with N2 cooled PTV injector, GC5 interface
·        [CO213C), N215N), H22H), CO (δ18O)]

Gas concentrator
·        CO2 and CH413C), N2O (δ15N),

High temperature combustion TOC analyzer, TOC cube, TOC cube interface
·        [CO213C), N215N)]
CO213C, δ18O), N215N), H2 (2H), SO234S)

Antwerp University Hospital – Gastroenterology and Hepatology

Antwerp University Hospital –   Gastroenterology and Hepatology

Wilrijkstraat 10, 2650 Edegem, B

Contact
Paul Pelckmans
paul.pelckmans@uza.be
32(0)38213323

Research line
Health and Disease

Topics
13C breath tests
urea – 13C
mixed triglyceride – 13C
octanoic acid – 13C
d-glucose u –13C6
aminopyrine – 13C2
lactose – 13C

Isotopes
13C

Instruments
GC/IRMS

IRMS Sercon ABCA V

Federal Agency for the Safety of the Food Chain – Residues and Contaminants

Federal Agency for the Safety of the Food Chain – Residues and Contaminants

Braemkasteelstraat 59,  9050 Gentbrugge, B

Contact
Eva Gorrebeeck
eva.Gorrebeeck@favv.be
32(0)92102186

Research line
Food safety

Topics
Agriculture/Public Health
Residues and Contaminants
Method development
Detection of abuse of natural hormones and their precursors
Bovines

Isotopes
13C

Instruments
GC/C/IRMS/MS

Trace GC Ultra; DSQ II; MAT 253

Ghent University Faculty of Medicine – Doping Control Laboratory

Ghent University Faculty of Medicine – Doping Control Laboratory

Technologiepark 30, 9052 Zwijnaarde, B

Contact
Michaël Polet
michael.polet@ugent.be
32(0)93313296

Research line
Doping control

Topics
distinguish between endogenous steroids and their synthetic copies
improving the existing methods
expanding them with new compounds.

Isotopes
13C

Instruments
GC/C/IRMS

ThermoScientific, MAT253

Ghent University – Isotope Bioscience Laboratory (ISOFYS)

Ghent University – Isotope Bioscience Laboratory  (ISOFYS)

Coupure Links 653, 9000 Gent, B

Contact
Prof. Pascal Boeckx
Pascal.Boeckx@UGent.be
Ugent Stable Isotope Facility
32(0)92646000

Research line
Analytical development, Ecology, Geology

Topics
agronomy, biogeochemistry, ecology, paleoclimatology, hydrology, climate change impacts and adaptation, soil conservation and isotope forensics
new analytical protocols for stable isotopes

Isotopes
13C, 15N, 18O, 2H

Instruments
EA/C/IRMS, TC-EA/IRMS, TG-IRMS, GC/C/IRMS, LC/C/IRMS, SIRIS

EA-IRMS: ANCA-SL (Autom N C Analyser – Solids and Liquids) / SerCon 20-20 IRMS (SysCon electronics)
TC-EA-IRMS: A Sercon ht furnace (1400ºC thermal decomp elem analyser) / Sercon 20-20 IRMS (SysCon electronics)
TG-IRMS: ANCA-TGII (Autom N C Analyser – Trace Gases) / SerCon 20-20 IRMS (SysCon electronics) with cryogenic trapping and focusing of samples
GC-IRMS: A Finnigan Trace GC Ultra with combustion interface (GC combustion III) coupled to a Finnigan DeltaplusXP
LC-IRMS: A Finnigan Surveyor HPLC with LC-IsoLINK interface coupled to a Finnigan DeltaPLUSXP
Wavelength-Scanned Cavity Ring-Down Spectroscopy Analyser Isotopic Water Analyser: Model L1102-i, Picarro

Groningen University – Centre for Isotope Research

Groningen University – Centre for Isotope Research

Nijenborch 4, 9747 AG Groningen,NL

Contact
Prof. Harro A.J.Meijer
h.a.j.meijer@rug.nl
31(0)503634760

Research line
Analytical development, Atmospheric research

Isotopes
13C, 15N, 17O, 18O, 2H, 14C

Instruments
AMS, DI-IRMS, EA/C/IRMS, EA/P/IRMS, SIRIS

AMS                           14C
SIRA10                       13C, 18O
DI-Optima                  13C, 18O
Air-Optima                  O2/N2
Optima                       13C, 15N
IsoPrime                      2H, 18O
IsoPrime100               13C, 18O, 2H, 32S
ICOGS (laser)            14C
Sara (laser)                2H, 17O, 18O