Archieven

Academic Medical Center Amsterdam – Clinical Chemistry / Woman and Child / Endocrinology

Academic Medical Center Amsterdam – Clinical Chemistry /  Woman and Child / Endocrinology

PO Box 22660, 1100DD Amsterdam / Meibergdreef 9, 1100AZ Amsterdam, NL

Contact:
Henk Schierbeek
h.schierbeek@amc.uva.nl
31(0)205666299

Research line
Health and Disease

Topics
metabolic kinetics
amino acids, peptides, carbohydrates, protein synthesis, energy expenditure
neonates, adults, laboratory animals: mouse, rat, pig, baboon
insulin resistance, lungs (surfactant), gut, oxidative stress and malnutrition

Isotopes
13C, 15N, 18O, 2H

Instruments
LC/MS/MS, GC/MS/MS, GC/C/IRMS, EA/C/IRMS, SIRIS, GC/MS, LC/C/IRMS

LCMS\MS, Waters, Premier, Triple quad
LCMS\MS, Waters, Xevo, Triple quad
LCMS\MS, Thermo Fisher, Velos pro, Linear Trap
GCMS\MS, Agilent 7000 GC\QQQ, Triple quad
GCMS, Agilent 5975C, Single quad
GCMS, Agilent 5973, Single quad
GCMS, Agilent 5973, Single quad
IRMS, Thermo Fisher, Delta plus
– GC/C/IRMS (+ Headspace)
IRMS, Thermo Fisher, Delta XP plus
– GC/C/IRMS
– LC/C/IRMS
– TCEA/IRMS
– Con Flow EA/IRMS
Infrared Spectrometer, Fisher, Helifan, CO2 analysis

Groningen University Medical Center – Center for Liver, Digestive and Metabolic diseases

Groningen University Medical Center – Center for Liver, Digestive and Metabolic diseases

PO Box 30.001, 9700 RB Groningen
Hanzeplein 1, 9713GZ Groningen, NL

Contact
Bert Groen
a.k.groen@umcg.nl
31(0)503632669

Research line
Health and Disease

Topics
Arteriosclerosis (cholesterol and bile acid metabolism)
Diabetes Mellitus (glucose, lipid metabolism)
men, rats, various mouse models and cell cultures
regulation of metabolic pathways
kinetics of metabolic pathways applying tracer technology
colon delivery device
cholesterol, bile acids, glucose, palmitic acid, stearic acid, oleic acid, urea, bicarbonate, breath CO2
kinetic studies in mouse blood, requiring frequent sampling of minimal blood spots

Isotopes
13C, 15N, 2H

Instruments
GC/C/IRMS, GC/P/IRMS, GC/MS, LC/MS/MS

Agilent 6890 GC/ Finnigan DeltaplusXL IRMS with CTC Pal autosampler
Two Agilent 6890 GC/ 5975 quadrupole MS with CTC Pal auto sampler
Perkin ElmerLC/API 3000 MS/MS with Perkin Elmer auto sampler
Shimadzu LC/API 3000 MS/MS with Shimadzu auto sampler

Research Institute for Chromatography – Research & Development

Research Institute for Chromatography – Research & Development

Pres. Kennedypark 26
8500 Kortrijk, Belgium

Contact
Emmie Dumont
emmied@richrom.com
32(0)56204031

Research line
Analytical development

Topics
optimization of the chromatographic separation before IRMS
implementation of 2D-GC and 2D-LC
complex natural samples.

Isotopes
13C, 15N, 2H

Instruments
GC/Py/IRMS, 2D-GC/Py/IRMS, LC/C/IRMS

GC-C/Py-IRMS (Agilent GC 7890 + Thermo delta V advantage)
2D-GC-C/Py-IRMS
LC-C-IRMS (All Thermo)